- The problem
- Spartan Motors USA (Spartan) is recalling certain 2004-2016 Emergency Response Gladiator Tractor Drawn Aerial vehicles. Cracks may develop and extend into the vertical portions of the tiller frame, resulting in instability of the aerial device.
- The risk
- If the aerial device becomes unstable, the device may fall, increasing the risk of an injury.
- The fix
- Spartan will notify owners, and dealers will inspect and correct any cracking, and add reinforcements to prevent any possible future cracking, free of charge. The recall began May 13, 2019. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 19007.
Equipment & accessories
2015 Spartan Gladiator Equipment problems
No owner has filed a complaint about the 2015 Spartan Gladiator's equipment & accessories with NHTSA. Trailer hitches, mobility equipment, accessories and aftermarket parts.
- Complaints
- 0
- Recalls
- 6
- Crashes
- 0
- Fires
- 0
- Injuries
- 0
- Deaths
- 0
Equipment recalls for the 2015 Spartan Gladiator
- The problem
- Spartan Motors USA (Spartan) is recalling certain 2001-2019 Spartan MetroStar and Gladiator emergency vehicles. The mounting fasteners for the Emergency Medical Service (EMS) cabinets may not be the correct size, allowing the cabinets to break free from their mountings in the event of a crash.
- The risk
- If the EMS cabinets become loose during a crash, the cabinets may become projectiles, increasing the risk of injury.
- The fix
- Spartan will notify owners, and dealers will replace the incorrect size fasteners with the correct fasteners, free of charge. The recall began November 30, 2018. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 18030.
- The problem
- Spartan Motors USA (Spartan) is recalling 2014-2017 Spartan Gladiator and MetroStar emergency response vehicles equipped with Hale pressure relief valves in the water pumps used for fire fighting. Rings securing the valves may corrode over time after exposure to water, causing the ring to fail and the pressure relief valve to open, reducing the water pressure available for fire fighting.
- The risk
- A reduction in water pressure may hinder fire fighting efforts, increasing the risk of injury.
- The fix
- Spartan will notify owners and Hale service providers will install a remedy kit, free of charge. The recall began on December 11, 2017. Owners may contact Spartan customer service at 1-800-543-5008 or Hale customer service at 1-800-533-3569. Spartan's number for this recall is 17028.
- The problem
- Spartan Motors (Spartan) is recalling certain model year 2015 Gladiator and MetroStar Emergency Response vehicles manufactured June 3, 2015, to March 16, 2016, equipped with pumps to provide pressurized water to aid in fighting fires. These pumps have 6" intake strainers that may have been improperly soldered during production and, as a result, the strainers may come apart during use, allowing parts of the strainer and debris to enter the pump, possibly damaging the pump.
- The risk
- If the strainer and/or debris enters the pump, and the operator is forced to shut down the pump, reducing firefighting effectiveness, there could be an increased risk of injury.
- The fix
- Spartan will notify owners to check the strainer for missing solder at the joints. Any strainers missing solder will be replaced, free of charge. The recall began on June 10, 2016. Owners may contact Spartan customer service at 1-800-543-5008 or Hale Products Customer Service Center at 1-800-533-3569. Spartan's number for this recall is 16012.
- The problem
- Spartan Motors USA (Spartan) is recalling certain model year 2014-2015 Gladiator and MetroStar emergency vehicles manufactured from November 18, 2014, through July 9, 2015. Under certain conditions, the fire-suppression-agent tank level pressure sensor may register an incorrect reading. This may result in the reading to indicate more agent (typically water or fire fighting foam) left in the tank than actually is.
- The risk
- If there is an incorrect reading of agent in the tank, it can increase the risk of injury to the fire fighter if the tank unexpectedly runs out of agent.
- The fix
- Spartan will notify owners, and dealers will recalibrate the tank level system or supply a new sensor, free of charge. The recall began on March 30, 2016. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 16003.
- The problem
- Spartan Motors, Inc. (Spartan) is recalling certain model year 2013-2015 Gladiator, and 2011 and 2013-2014 MetroStar emergency vehicles manufactured June 15, 2011, to January 14, 2014. The affected vehicles are equipped with a pressure governor or hand throttle supplied by Fire Research Corporation (FRC). Due to an issue with the software for the pressure governor or hand throttle, the affected vehicles may experience an engine surge.
- The risk
- A surge in engine speed can cause increased water pressure at the end of a fire hose, increasing the risk of personal injury.
- The fix
- Spartan will notify owners, and dealers will install a software update, free of charge. The recall began in September 2014. Owners may contact Spartan customer service at 1-517-543-6400. Spartan's number for this recall is 14013.
Equipment complaints
No complaints about this area yet.
Spartan Gladiator equipment complaints by year
Gladiator equipment problems, every yearSource: U.S. National Highway Traffic Safety Administration (NHTSA) complaints and recalls, checked . Complaints are owners' own reports and are not verified. How we use the data