- The problem
- On certain motor homes equipped with with a 3.2 Qd cummins onan generator, the generator's internal controller may fail; however, the electrical circuits would remain energized. Included in these circuits is the electronic preheated element which aids cold starts at ambient temperatures below 0 degrees celsius. In normal operation, this circuit is energized no longer than 120 seconds at 30 celsius. If the circuit remains energized beyond the designed period, the preheated element can over heat.
- The risk
- If the element over heats, a fire in the air intake system could occur.
- The fix
- Winnebago is working with cummins to replace the generators free of charge (please see 07e076). Owners may contact cummins at 812-377-3713 or winnebago at 641-585-3535.
Equipment & accessories
2008 Winnebago View Equipment problems
No owner has filed a complaint about the 2008 Winnebago View's equipment & accessories with NHTSA. Trailer hitches, mobility equipment, accessories and aftermarket parts.
- Complaints
- 0
- Recalls
- 1
- Crashes
- 0
- Fires
- 0
- Injuries
- 0
- Deaths
- 0
Equipment recalls for the 2008 Winnebago View
Equipment complaints
No complaints about this area yet.
Winnebago View equipment complaints by year
View equipment problems, every yearSource: U.S. National Highway Traffic Safety Administration (NHTSA) complaints and recalls, checked . Complaints are owners' own reports and are not verified. How we use the data