- The problem
- Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
- The risk
- The reduced visibility of the turn signals can increase the risk of a crash.
- The fix
- Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
Vehicle safety record
2003 Gillig Low Floor Problems, complaints & recalls
Owners have filed 1 complaint about the 2003 Gillig Low Floor with NHTSA, most often about the lights (1). It is covered by 9 recalls, the latest in June 2018 for the flasher unit. For comparison, the 2002 has 0 and the 2004 has 0.
NHTSA data checked
CAbout as many problems as a typical Low Floor year, for its age
#427 most complained-about 2003 vehicle
- Complaints
- 1
- Recalls
- 9
- Crashes
- 0
- Fires
- 0
- Injuries
- 0
- Deaths
- 0
Most common 2003 Gillig Low Floor problems
Share of all 1 complaints. One complaint can name more than one area. Tap an area for its complaints and recalls.
2003 Gillig Low Floor recalls 9
Recall repairs are free. Your dealer fixes them whether or not you bought the car there - check your VIN at nhtsa.gov/recalls to see if yours is done. What to do
- The problem
- Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
- The risk
- The reduced visibility of the turn signals may increase the risk of a crash.
- The fix
- Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
- The problem
- Gillig corporation is recalling certain model year 2001 through 2009 transit buses manufactured between january 2001 and september 2009 equipped with luminator horizon led side destination signs. The connector board can corrode due to an accumulation of moisture under the connector.
- The risk
- A short could occur, possibly causing smoke and fire.
- The fix
- Gillig will notify owners and luminator will repair the buses free of charge. The safety recall began on spetember 29, 2009. Owners may contact luminator at 1-972-516-3033 or gillig field services at 1-800-735-1500.
- The problem
- On certain transit buses built with cummins isl and isc diesel engines equipped with the cm850 fuel system, the engine high pressure fuel lines, from the engine high pressure pump to the engine fuel rail, are prone to failure.
- The risk
- Failure of the line introduces high pressure fuel spray into the engine compartment which can ignite when it comes in contact with a hot surface.
- The fix
- Cummins will install a fuel line bracket to reduce fuel line stress. A new fuel line will be installed when adding the bracket (please see 06e037). Gillig notified customers on november 22, 2006. Customers may contact cummins at 1-800-343-7357 or gillig at 510-264-5031.
- The problem
- On certain transit buses manufactured with detroit diesel series 50 engines, the electronic control module (ecm) will need to be reprogrammed to activate the exhaust temperature sensor.
- The risk
- Engine malfunction could possible lead to engine and vehicle damage and potential for a vehicle fire.
- The fix
- Gillig is working with detroit diesel to reprogram the engines. Gillig issued a renotification letter to owners on february 27, 2007. Owners may contact detroit diesel at 1-313-592-5791 or gillig at 1-510-785-1500.
- The problem
- Certain gillig buses equipped with sure-lok wheelchair tie-down securement assemblies. The sprocket teeth of the retractor assembly may be out of alignment causing the load pawl not to fully seat in the sprocket teeth.
- The risk
- In the event of a vehicle crash, the wheelchair may not be adequately secured possibly resulting in injuries.
- The fix
- Dealers will inspect and replace the wheelchair securement retractors as necessary. The recall began october 8, 2004. Owners should contact gillig at 1-800-735-1500..
- The problem
- On certain transit buses equipped with detroit diesel series 40 engines, the turbocharger can fail allowing lubricating oil to spill onto the engine.
- The risk
- This can result in a fire in the engine compartment.
- The fix
- Dealers will inspect and replace the turbocharger to prevent the possibility of an engine compartment fire. Detroit diesel is conducting owner notification and remedy for this campaign. Gillig issued a renotification letter to owners on february 27, 2007. Owners should contact detroit detroit diesel at 313-5923708 or gillig at 510-785-1500.
- The problem
- On certain phantom and low floor transit buses equipped with cummins 8.3L and 8.9L isc and isl diesel engines, oil can leak into the engine compartment from a crack in the cup plug.
- The risk
- Oil leakage on a hot engine can result in an engine compartment fire, possibly resulting in injuries.
- The fix
- Cummins will conduct the owner notification and remedy for this campaign. Cummins will isntall a steel cup plug boss cap on the affected engines. Owners should contact cummins customer assistance center at 1-800-343-7357 or gillig at 510-785-1500.
- The problem
- Certain low floor buses powered by a gaseous hydrogen fuel system. These transducers were made of 17-4 ph stainless steel material which may be susceptible to embrittlement in a high-pressure hydrogen application environment.
- The risk
- Embrittlement could potentially lead to a transducer diaphragm failure.
- The fix
- Dealers will replace the transducer. The recall began july 12, 2004. Owners should contact gillig at 1-510-785-1500.
What owners say
Problems or none - your experience is exactly what the next buyer is looking for. Write it now
1 complaints about the 2003 Gillig Low Floor
Newest first, as filed with NHTSA by owners.
Ann arbor transit purchased 19 new 2003 gillig (800.735.1500) Low floor 40'&35' transit buses, delivered october 2003. Immediately, ann arbor transit experienced both front exterior turn signal failures affecting all 19 new buses. The failures include burnt out bulbs, loose bulb socket metal contacts, lamp socket wiring harness falling off. Ann arbor transit has filed over forty warranty claims within the one year period only to be rejected. Ann arbor transit has spoken to gillig's service manager only to be told...
Read the full complaint
that we are the only customers with this problem. Gillig has supplied a new wiring harness to consider, but the new harness was rejected because it was identical to the existing. Gillig claims to be willing to help, but does nothing. Currently, all 19 buses should be considered a safety hazard due to the very unreliable front turn signal performance. Ann arbor transit operates about 90 large buses daily and is expected to provide safe, reliable, clean buses to all of our 4 million yearly customers, please help! *Nm
Gillig Low Floor: every year compared
All Low Floor yearsQuestions about the 2003 Gillig Low Floor
Does the 2003 Gillig Low Floor have any recalls?
Yes - NHTSA lists 9 recalls for the 2003 Gillig Low Floor: flasher unit (June 2018); turn signal (February 2017); interior lighting (September 2009); fuel system, diesel (November 2006) and more. Recall repairs are free at any authorized dealer. Enter your VIN at nhtsa.gov/recalls to see whether yours has been fixed.
What are the most common problems with the 2003 Gillig Low Floor?
By the complaints owners filed with NHTSA, the most common problem areas are the lights (1).
How many complaints has the 2003 Gillig Low Floor had?
1 complaints have been filed with NHTSA, the first on November 24, 2004 and the latest on November 24, 2004. Of these, 0 describe a crash and 0 a fire, and together they report 0 injuries and 0 deaths.
Is the 2003 Gillig Low Floor a reliable vehicle?
Its Safety Index is 56 out of 100 (grade C: about as many problems as a typical Gillig Low Floor year, for its age). The index weighs complaints, crashes, fires, injuries, deaths and recalls against how long the vehicle has been on the road, compared with the same model's other years. It is not a measure of every repair - read the complaints and owner experiences, and have any used vehicle inspected before you buy.
Which Gillig Low Floor years have the most complaints?
2016 (2), 2000 (1), 2003 (1). See every Gillig Low Floor year compared.
What should I do if my 2003 Gillig Low Floor has a problem?
If it is a safety problem, stop driving it if it is unsafe and contact your dealer. Report it to NHTSA at nhtsa.gov/report-a-safety-problem - enough reports start investigations and recalls - and share your experience here so other owners know what to look for.