- The problem
- Grand Design RV, LLC is recalling certain 2018-2019 Reflection fifth wheel trailers, models 28BH and 29RS. The circuit for the power converter does not have over-current protection.
- The risk
- An electrical short circuit in the unprotected circuit can increase the risk of a fire.
- The fix
- Grand Design RV will notify owners, and dealers will inspect the trailers to determine if the 50-amp mini breaker at the bus bar is installed correctly and that the circuit is wired correctly, correcting it as necessary, free of charge. The recall began November 19, 2018. Owners may contact Grand Design RV customer service at 1-574-825-9679. Grand Design RV's number for this recall is 910017.
Electrical system
2019 Grand Design Reflection Electrical problems
Owners have filed 2 complaints about the 2019 Grand Design Reflection's electrical system with NHTSA - 22% of all its complaints, most recently on June 8, 2021. Dead batteries, warning lights, wiring, alternators, infotainment and electronic module failures.
- Complaints
- 2
- Recalls
- 2
- Crashes
- 0
- Fires
- 0
- Injuries
- 0
- Deaths
- 0
Electrical recalls for the 2019 Grand Design Reflection
- The problem
- Grand Design RV, LLC (Grand Design) is recalling certain 2019 Grand Design Reflection travel trailers, models 285BHTS, 287RLTS and 297RSTS. The wires to the 50 amp mini-breaker may be installed incorrectly, leaving the circuit unprotected.
- The risk
- If the unprotected circuit overheats or experiences a short, it can increase the risk of a fire.
- The fix
- Grand Design will notify owners, and dealers will inspect the 50 amp mini-breaker to make sure that it is wired correctly, re-wiring it as necessary, free of charge. The recall began November 12, 2018. Owners may contact Grand Design customer service at 1-574-825-9679. Grand Design's number for this recall is 910016.
Electrical complaints
The contact owns a 2019 Grand Design Recreational Reflection. The contact stated that there were wires located underneath one of the slide out beds. While sliding out the bed, the bed rubbed against the wire and caused the wires to short circuit. The contact lost power to certain lights located in the bedroom due to the design. The contact called an independent mechanic who redirected the wires from underneath the slide out bed. The manufacturer was not notified of the failure. The vehicle was repaired. The failure mileage was approximately 6,000.
I have an unsafe and potentially dangerous wiring problem on my rv. The heater and the refrigerator are wired on the same circuit breaker (spliced together). When the heater turns on, the fridge power flashes on and off for a moment until the heater is running normally. This kind of surge on the circuit is unsafe and can cause damage to other electrical components and/or fire. The control board for the fridge has already been replaced as per bish's rv. I have notified grand design about this in a survey...
Read the full complaint
(04/2019). Shortly after that, I received an email from [[redacted]] asking about my concerns (04/10/2019) I described in the survey. I also received a phone call from grand design, I believe on 04/11/2019. I spoke with this representative and explained the wiring issue and told him that I thought it was wired on the same circuit breaker. He informed me that they do not wire their rv's in such a way and stated that, I must have been hit by lightning that caused the issue. Bish's rv tried to get grand design to approve the electrical work as warranty. Grand design refused twice (on the same date of 05/02/2019). Grand design stated that the heater and fridge do not draw more than 15 amps while running simultaneously. I believe they are forgetting the peak amperage at start up that is causing this issue. I believe this issue has potential to cause severe injury and even death, unless it is properly resolved. It has already caused a premature failure of the fridge control board. As per the national electrical code article 551 states that an rv must comply with all of the other requirements if it has a power source that is 120v, 120/208v, or 120/240v [551.4]. Information redacted pursuant to the freedom of information act (foia), 5 u.S.C. 552(B)(6). *Tr
Grand Design Reflection electrical complaints by year
Reflection electrical problems, every yearSource: U.S. National Highway Traffic Safety Administration (NHTSA) complaints and recalls, checked . Complaints are owners' own reports and are not verified. How we use the data